Approval: CE, UKCA, cULus, EAC(Eurasian), TÜV
Sensor principle:Transponder
Coding level to ISO 14119: low
Classification to EN 60947-5-3: PDDB
Transponder coding: coded
Suitable for series connection: yes
Supply voltage (V): 24 V
Type of supply voltage U1: DC
Power consumption DC: 1
Number of inputs: 2
DC voltage at input: 24 V DC
Number of OSSD outputs: 2
Number of sig. outputs: 1
Potential isolation S/C O: no
S/C output short circuit proof: yes
Utilisation cat. to EN 60947-1: DC-12
Ambient temperature standard: EN 60068-2-14
Ambient temperature: -25 °C
Max. ambient temp. at Hmax: +60 °C
Max. ambient temp. at 2000 m: +70 °C
Storage temperature standard: EN 60068-2-1/-2
Climatic suitability standard: EN 60068-2-78
Humidity rating: 93 % r. h. at 40 °C
Perm. operating height ASL: 4000 m
EMC to standard ...: EN 60947-5-3
Vibration to standard ...: EN 60947-5-2
Acc. shock to standard1: 30g
Overvoltage category: III
Pollution degree clear. Creep.: 3
Protection type housing: IP6K9K
Change op. dist. temp.change: +-0.01 mm/°C
Bend radius (when laying) K1: 5 x Ø
Type 1 actuator: PSEN cs3.1
Sensor can be flush-mounted: yes, follow installation guide
Connection type: M12, 8-pin male
Cable lines: Li9Y11Y 8 x 0.14 mm²
Housing material upper part: PBT
Height dimension: 37 mm
Width dimension: 26 mm
Depth dimension: 18 mm
Net weight: 50 g
Gross weight: 70 g
Operating frequency: 122 kHz - 128 kHz